summaryrefslogtreecommitdiff
path: root/include/linux/iio/adc
diff options
context:
space:
mode:
Diffstat (limited to 'include/linux/iio/adc')
-rw-r--r--include/linux/iio/adc/qcom-vadc-common.h27
1 files changed, 14 insertions, 13 deletions
diff --git a/include/linux/iio/adc/qcom-vadc-common.h b/include/linux/iio/adc/qcom-vadc-common.h
index aa21b032e861..3bf4c49726a7 100644
--- a/include/linux/iio/adc/qcom-vadc-common.h
+++ b/include/linux/iio/adc/qcom-vadc-common.h
@@ -83,27 +83,27 @@ struct vadc_linear_graph {
/**
* enum vadc_scale_fn_type - Scaling function to convert ADC code to
* physical scaled units for the channel.
- * SCALE_DEFAULT: Default scaling to convert raw adc code to voltage (uV).
- * SCALE_THERM_100K_PULLUP: Returns temperature in millidegC.
+ * @SCALE_DEFAULT: Default scaling to convert raw adc code to voltage (uV).
+ * @SCALE_THERM_100K_PULLUP: Returns temperature in millidegC.
* Uses a mapping table with 100K pullup.
- * SCALE_PMIC_THERM: Returns result in milli degree's Centigrade.
- * SCALE_XOTHERM: Returns XO thermistor voltage in millidegC.
- * SCALE_PMI_CHG_TEMP: Conversion for PMI CHG temp
- * SCALE_HW_CALIB_DEFAULT: Default scaling to convert raw adc code to
+ * @SCALE_PMIC_THERM: Returns result in milli degree's Centigrade.
+ * @SCALE_XOTHERM: Returns XO thermistor voltage in millidegC.
+ * @SCALE_PMI_CHG_TEMP: Conversion for PMI CHG temp
+ * @SCALE_HW_CALIB_DEFAULT: Default scaling to convert raw adc code to
* voltage (uV) with hardware applied offset/slope values to adc code.
- * SCALE_HW_CALIB_THERM_100K_PULLUP: Returns temperature in millidegC using
+ * @SCALE_HW_CALIB_THERM_100K_PULLUP: Returns temperature in millidegC using
* lookup table. The hardware applies offset/slope to adc code.
- * SCALE_HW_CALIB_XOTHERM: Returns XO thermistor voltage in millidegC using
+ * @SCALE_HW_CALIB_XOTHERM: Returns XO thermistor voltage in millidegC using
* 100k pullup. The hardware applies offset/slope to adc code.
- * SCALE_HW_CALIB_THERM_100K_PU_PM7: Returns temperature in millidegC using
+ * @SCALE_HW_CALIB_THERM_100K_PU_PM7: Returns temperature in millidegC using
* lookup table for PMIC7. The hardware applies offset/slope to adc code.
- * SCALE_HW_CALIB_PMIC_THERM: Returns result in milli degree's Centigrade.
+ * @SCALE_HW_CALIB_PMIC_THERM: Returns result in milli degree's Centigrade.
* The hardware applies offset/slope to adc code.
- * SCALE_HW_CALIB_PMIC_THERM: Returns result in milli degree's Centigrade.
+ * @SCALE_HW_CALIB_PMIC_THERM: Returns result in milli degree's Centigrade.
* The hardware applies offset/slope to adc code. This is for PMIC7.
- * SCALE_HW_CALIB_PM5_CHG_TEMP: Returns result in millidegrees for PMIC5
+ * @SCALE_HW_CALIB_PM5_CHG_TEMP: Returns result in millidegrees for PMIC5
* charger temperature.
- * SCALE_HW_CALIB_PM5_SMB_TEMP: Returns result in millidegrees for PMIC5
+ * @SCALE_HW_CALIB_PM5_SMB_TEMP: Returns result in millidegrees for PMIC5
* SMB1390 temperature.
*/
enum vadc_scale_fn_type {
@@ -120,6 +120,7 @@ enum vadc_scale_fn_type {
SCALE_HW_CALIB_PMIC_THERM_PM7,
SCALE_HW_CALIB_PM5_CHG_TEMP,
SCALE_HW_CALIB_PM5_SMB_TEMP,
+ /* private: */
SCALE_HW_CALIB_INVALID,
};