docs/library/machine.UART: Add notes about UART init and deinit.
* `init()` can be called multiple times to reconfigure UART. * After `deinit()` it is impossible to call `init()` again. Signed-off-by: Tomasz 'CeDeROM' CEDRO <tomek@cedro.info>
Diffstat (limited to 'docs/library')
-rw-r--r--docs/library/machine.UART.rst12
1 files changed, 12 insertions, 0 deletions
diff --git a/docs/library/machine.UART.rst b/docs/library/machine.UART.rst
index e23952573..1d54174c9 100644
--- a/docs/library/machine.UART.rst
+++ b/docs/library/machine.UART.rst
@@ -87,10 +87,22 @@ Methods
When no pins are given, then the default set of TX and RX pins is taken, and hardware
flow control will be disabled. If *pins* is ``None``, no pin assignment will be made.
+ .. note::
+ It is possible to call ``init()`` multiple times on the same object in
+ order to reconfigure UART on the fly. That allows using single UART
+ peripheral to serve different devices attached to different GPIO pins.
+ Only one device can be served at a time in that case.
+ Also do not call ``deinit()`` as it will prevent calling ``init()``
+ again.
+
.. method:: UART.deinit()
Turn off the UART bus.
+ .. note::
+ You will not be able to call ``init()`` on the object after ``deinit()``.
+ A new instance needs to be created in that case.
+
.. method:: UART.any()
Returns an integer counting the number of characters that can be read without